You are here

CONVAL® service release 7.0.9

Category: 
Updates
- posted 28. May 2009 - 14:51

The CONVAL Service Release 7.0.9 fixes the following issues:

  • Control valve
    There is an issue with the computation of the downstream pressure p2 for gases and vapours with given data for upstream pressure, Cv value and flow: The calculated value of p2 is too high.
  • Tank depressurization
    The initial mass flow during the depressurization of tanks with high pressure gases is calculated too high and thus the depressurization time is partly significantly too low.
  • Shell-and-tube heat exchanger
    The Mean logarithmic temperature difference of counter-flow heat exchangers with more than one cycle is computed too high and the heat exchanger is under-sized in such cases.

Details can be found on the download page in the version history and in the known bugs section.