The CONVAL Service Release 7.0.10 fixes the following issues:

  • Control valve

    If using silencers with a bore diameter larger than 10 mm the number of bores in the downstream resistance structures section was not calculated correctly.

  • Control valve

    Due to an error at the implementation of the standards IEC 60534-8-3:2000 and ISA-75.17:1989 valves with high outlet Mach numbers were calculated too loud.

  • Restriction orifice plate
    The formulas used in the CONVAL restriction orifice calculation are only valid up to a ratio d/Di < 0.75, with throttle orifice d and pipe inside diameter Di. Unfortunately there was no warning if the ratio exceeds this value.

Details can be found on the download page in the version history and in the known bugs section.